منظومة تنقية سوائل التبريد والتشحيمZyklomat
ZKR 14/350
منظومة تنقية سوائل التبريد والتشحيم
Zyklomat
ZKR 14/350
سنة الصنع
٢٠١٦
الحالة
مستعمل
الموقع
ألمانيا 

البيانات الأساسية
- اسم الماكينة:
- منظومة تنقية سوائل التبريد والتشحيم
- الشركة المصنعة:
- Zyklomat
- طراز:
- ZKR 14/350
- سنة الصنع:
- ٢٠١٦
- الحالة:
- مستعمل
السعر والموقع
- الموقع:
- Deutschland

اتصل
تفاصيل العرض
- معرّف الإعلان:
- A22612042
- رقم المرجع:
- M2203
- تحديث:
- آخر مرة في 25.11.2026
وصف
Coolant cleaning system
Manufacturer: Zyklomat
Type: ZKR 14/350
Year of manufacture: 2016
For cleaning grinding emulsions
Supply: max. approx. 250 L/min. at approx. 3.5 bar water
Transfer to the filter system is provided on-site, air- and foam-free.
Maximum temperature: 50°C
Cleaning capacity: 350 L/min.
Recirculation from clean tank to dirty tank: 100-350 L/min.
Machine supply: max. 250 L/min.
Filtration principle: ZYKLOMAT high-performance hydrocyclone Z1B-9/3
Separation particle size: approx. 5 µm
Medium: 3-6% emulsion
Operating temperature: ambient temperature
Solid particle content: approx. 5.14 m3
Maximum operating volume: approx. 4.58 m3
Minimum operating volume: approx. 3.60 m3
Process sequence:
fully automatic full-flow filtration
Psdpfxozwccms Aphsgw
Sludge discharge:
fully automatic, with consistent consistency
The dirty liquid is fed via on-site lift stations.
The chips and fine sludge generated during grinding
(grinding debris, scale, corundum) are discharged via a scraper conveyor.
In the upper scraper section, the sludge is pre-dried.
Filtration takes place via ZYKLOMAT high-performance hydrocyclones.
The system operates fully automatically.
Maintenance: annual maintenance
Availability: 10-2026
Double scraper tank for discharging grinding sludge
Type: KR 1.75-5.1
Total volume: approx. 5.14 m3
Maximum volume: approx. 4.58 m3
Length: approx. 4,000 mm, including 70 mm stiffening
Width: approx. 1,890 mm, including 140 mm stiffening
Height: approx. 1,105 mm, including 100 mm bottom profile
Neck height: approx. 2,300 mm
Theoretical maximum discharge volume: 15 kg/h
Function:
Coolant storage tank with integrated clean tank,
sedimentation and flotation tank with
fully automatic sludge discharge.
1 spur gear motor
Voltage 400 V, 50 Hz, IP 54 as scraper drive
3 connection nozzles for return lines from three machines
1 clean liquid tank, integrated in the scraper tank at the rear, oil-tight welded, with internal circumferential bevel gear, various cover plates (non-walkable plates screwed onto angular frames), without ladder, without railing, without internal access rungs
Maximum volume: approx. 0.55 m3
251126ä
تمت ترجمة الإعلان تلقائيًا. قد تحدث أخطاء في الترجمة.
Manufacturer: Zyklomat
Type: ZKR 14/350
Year of manufacture: 2016
For cleaning grinding emulsions
Supply: max. approx. 250 L/min. at approx. 3.5 bar water
Transfer to the filter system is provided on-site, air- and foam-free.
Maximum temperature: 50°C
Cleaning capacity: 350 L/min.
Recirculation from clean tank to dirty tank: 100-350 L/min.
Machine supply: max. 250 L/min.
Filtration principle: ZYKLOMAT high-performance hydrocyclone Z1B-9/3
Separation particle size: approx. 5 µm
Medium: 3-6% emulsion
Operating temperature: ambient temperature
Solid particle content: approx. 5.14 m3
Maximum operating volume: approx. 4.58 m3
Minimum operating volume: approx. 3.60 m3
Process sequence:
fully automatic full-flow filtration
Psdpfxozwccms Aphsgw
Sludge discharge:
fully automatic, with consistent consistency
The dirty liquid is fed via on-site lift stations.
The chips and fine sludge generated during grinding
(grinding debris, scale, corundum) are discharged via a scraper conveyor.
In the upper scraper section, the sludge is pre-dried.
Filtration takes place via ZYKLOMAT high-performance hydrocyclones.
The system operates fully automatically.
Maintenance: annual maintenance
Availability: 10-2026
Double scraper tank for discharging grinding sludge
Type: KR 1.75-5.1
Total volume: approx. 5.14 m3
Maximum volume: approx. 4.58 m3
Length: approx. 4,000 mm, including 70 mm stiffening
Width: approx. 1,890 mm, including 140 mm stiffening
Height: approx. 1,105 mm, including 100 mm bottom profile
Neck height: approx. 2,300 mm
Theoretical maximum discharge volume: 15 kg/h
Function:
Coolant storage tank with integrated clean tank,
sedimentation and flotation tank with
fully automatic sludge discharge.
1 spur gear motor
Voltage 400 V, 50 Hz, IP 54 as scraper drive
3 connection nozzles for return lines from three machines
1 clean liquid tank, integrated in the scraper tank at the rear, oil-tight welded, with internal circumferential bevel gear, various cover plates (non-walkable plates screwed onto angular frames), without ladder, without railing, without internal access rungs
Maximum volume: approx. 0.55 m3
251126ä
تمت ترجمة الإعلان تلقائيًا. قد تحدث أخطاء في الترجمة.
إرسال طلب
هاتف & فاكس
+49 7022 ... إعلانات
قد تهمك أيضًا هذه الإعلانات.
ناجح
تم إرسال رسالتك.
إعلان صغير
ألمانيا
٣٬٢٠٨ km
منظومة معالجة سائل التبريد والتشحيم
ZyklomatZKR 14/350
ZyklomatZKR 14/350
ناجح
تم إرسال رسالتك.
إعلان صغير
Salzburg
٢٬٨٠١ km
مركز تشغيل عام
DMG MORIDMU 40 eVo linear
DMG MORIDMU 40 eVo linear
ناجح
تم إرسال رسالتك.
إعلان صغير
Wien
٢٬٦٨٩ km
خط إنتاج صواني البيض المستخدم الكامل
Eco Recycle EquipFM-3500
Eco Recycle EquipFM-3500
ناجح
تم إرسال رسالتك.
إعلان صغير
Lindlar
٣٬٣٤٣ km
آلة تلميع
Weiz Industrie- und RobotertechnikRPM500_OSZ2
Weiz Industrie- und RobotertechnikRPM500_OSZ2
ناجح
تم إرسال رسالتك.
إعلان صغير
Ankara
١٬٤٧٢ km
آلة قطع ليزر محمية بالكامل
BodorC Series 12KW
BodorC Series 12KW
ناجح
تم إرسال رسالتك.
إعلان صغير
Siegen
٣٬٢٩٦ km
ماكينة تفريز بعمود متحرك
SoraluceFP8000
SoraluceFP8000
ناجح
تم إرسال رسالتك.
إعلان صغير
Kreuztal
٣٬٣٠٦ km
مركز تشغيل رأسي
DMG MORIDMC 635 V ecoline
DMG MORIDMC 635 V ecoline
ناجح
تم إرسال رسالتك.
إعلان صغير
Oelde
٣٬٣٦٥ km
مركز بالقطع - عمودي
DECKEL MAHODMC 635 V New Design
DECKEL MAHODMC 635 V New Design
ناجح
تم إرسال رسالتك.
إعلان صغير
Bamberg
٣٬٠٨٠ km
مركز بالقطع العمودي
MikronUCP 600
MikronUCP 600
ناجح
تم إرسال رسالتك.
إعلان صغير
سويسرا
٣٬١٩٩ km
ناكامورا NTJ100
Nakamura-TomeNTJ100
Nakamura-TomeNTJ100
تم حذف إعلانك بنجاح
حدث خطأ