صومعة خرسانة مسلحةWolf KG Silobau
Stahlbetonsilo
صومعة خرسانة مسلحة
Wolf KG Silobau
Stahlbetonsilo
سنة الصنع
٢٠٠٥
الحالة
مستعمل
الموقع
Fischerbach 

بيانات عن الآلة
- اسم الماكينة:
- صومعة خرسانة مسلحة
- الشركة المصنعة:
- Wolf KG Silobau
- طراز:
- Stahlbetonsilo
- سنة الصنع:
- ٢٠٠٥
- الحالة:
- جيد (مستخدم)
السعر والموقع
- الموقع:
- Fischerbach, ألمانيا

اتصل
تفاصيل العرض
- معرّف الإعلان:
- A22307012
- تحديث:
- آخر مرة في 13.07.2026
وصف
We are offering this used Wolf KG Silobau reinforced concrete silo, manufactured in 2005.
Manufacturer: Wolf KG Silobau
Model: Reinforced concrete silo
Year of manufacture: 2005
Condition: good
Category ID: 399
Type: Reinforced concrete silo
Inner diameter: 6.0 m
Outer diameter: 6.2 m
Total height: approx. 13 m
Capacity: approx. 198 m³
Suitable for wood chips / sawdust
Complete foundation system available
The precast concrete segments of the container and the substructure are made of concrete with a strength class of B45 (equivalent to today's C35/45).
The silo contents (wood chip heating system) were damaged by a fire in March 2025.
A joint expert report from the insurance company and the policyholder came to the following conclusion:
- The reinforced concrete structure is statically sound with no significant fire damage.
- No impairment of the load-bearing capacity of the silo walls.
- No significant damage to the concrete precast elements.
Nlodpfszk Ehfex Aixef
If you have any questions or require further information, please feel free to send us a message or call us.
تمت ترجمة الإعلان تلقائيًا. قد تحدث أخطاء في الترجمة.
Manufacturer: Wolf KG Silobau
Model: Reinforced concrete silo
Year of manufacture: 2005
Condition: good
Category ID: 399
Type: Reinforced concrete silo
Inner diameter: 6.0 m
Outer diameter: 6.2 m
Total height: approx. 13 m
Capacity: approx. 198 m³
Suitable for wood chips / sawdust
Complete foundation system available
The precast concrete segments of the container and the substructure are made of concrete with a strength class of B45 (equivalent to today's C35/45).
The silo contents (wood chip heating system) were damaged by a fire in March 2025.
A joint expert report from the insurance company and the policyholder came to the following conclusion:
- The reinforced concrete structure is statically sound with no significant fire damage.
- No impairment of the load-bearing capacity of the silo walls.
- No significant damage to the concrete precast elements.
Nlodpfszk Ehfex Aixef
If you have any questions or require further information, please feel free to send us a message or call us.
تمت ترجمة الإعلان تلقائيًا. قد تحدث أخطاء في الترجمة.
مستندات
مورد
ملاحظة: سجّل مجانًا أو سجّل الدخول، للاطلاع على جميع المعلومات.
مسجل منذ: 2026
١ إعلان على الإنترنت
إرسال طلب
هاتف & فاكس
+49 7832 ... إعلانات
تم حذف إعلانك بنجاح
حدث خطأ