- وصف الآلة:
- مع رطوبة 270 لترًا
- المصنّع:
- Vötsch
- الموديل:
- Klimaprüfschrank VCS³ 7027-10
- الحالة:
- جيد جدًا (مستعمل)
السعر والموقع
- الموقع:
- Einsteinstraße 8a, 46325 Borken, Deutschland

اتصل
تفاصيل العرض
- معرّف القائمة:
- A18774686
- الرقم المرجعي:
- 24564
- التحديث الأخير:
- في ٢٦.٠٦.٢٠٢٥
الوصف
Vötsch
Type: VCS³ 7027-10
Vötsch Climatic Test Chamber, Water-Cooled
With a temperature change rate of 10 K/min
Hpsdpfx Afjv R Ty Tezsa
Temperature test data:
Temperature range -72°C to +180°C
Temperature deviation over time in the center of the work space ± 0.3 K to ± 0.5 K
Temperature deviation over space ± 0.5 K to ± 2.0 K
Temperature change rate
Heating: 10 K/min
Cooling: 14.5 K/min
Climatic test data:
Temperature range +10°C to +95°C
(Extended climatic range: 2°C/95% RH, controlled for a maximum of 2 hours)
Temperature deviation over time in the center of the work space ± 0.2 K to ± 0.3 K
Temperature deviation over space ± 0.5 K to ± 1.0 K
Humidity deviation in the center of the usable space: ± 1% to ± 3% RH
Humidity range: 10% to 98% RH
(Extended climate range: 2°C/95% RH, regulated for a maximum of 2 hours)
External dimensions: Width 780 x Depth 1895 x Height 1775 (mm)
Test chamber dimensions: Width 580 x Depth 615 x Height 750 (mm)
Test chamber volume: approx. 270 liters
Side opening 50 mm
Side opening 125 mm
Operating data:
LED strip 24 V, 6.8 W / 2 x halogen bulb 24 V, 50 W
Rated voltage: 3/N/PE AC 400 V±10%, 50 Hz
Rated power: 14 kW
Rated current: 26 A
Fuse, on-site: 63 A slow-blow
Refrigerant R404A/R-23
Weight approx. 835 kg
For your safety, please note the following information as a buyer!
The following steps are performed on our offered chambers in advance:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
تمت ترجمة الإعلان تلقائياً، وقد تكون هنالك بعض الأخطاء في الترجمة.
Type: VCS³ 7027-10
Vötsch Climatic Test Chamber, Water-Cooled
With a temperature change rate of 10 K/min
Hpsdpfx Afjv R Ty Tezsa
Temperature test data:
Temperature range -72°C to +180°C
Temperature deviation over time in the center of the work space ± 0.3 K to ± 0.5 K
Temperature deviation over space ± 0.5 K to ± 2.0 K
Temperature change rate
Heating: 10 K/min
Cooling: 14.5 K/min
Climatic test data:
Temperature range +10°C to +95°C
(Extended climatic range: 2°C/95% RH, controlled for a maximum of 2 hours)
Temperature deviation over time in the center of the work space ± 0.2 K to ± 0.3 K
Temperature deviation over space ± 0.5 K to ± 1.0 K
Humidity deviation in the center of the usable space: ± 1% to ± 3% RH
Humidity range: 10% to 98% RH
(Extended climate range: 2°C/95% RH, regulated for a maximum of 2 hours)
External dimensions: Width 780 x Depth 1895 x Height 1775 (mm)
Test chamber dimensions: Width 580 x Depth 615 x Height 750 (mm)
Test chamber volume: approx. 270 liters
Side opening 50 mm
Side opening 125 mm
Operating data:
LED strip 24 V, 6.8 W / 2 x halogen bulb 24 V, 50 W
Rated voltage: 3/N/PE AC 400 V±10%, 50 Hz
Rated power: 14 kW
Rated current: 26 A
Fuse, on-site: 63 A slow-blow
Refrigerant R404A/R-23
Weight approx. 835 kg
For your safety, please note the following information as a buyer!
The following steps are performed on our offered chambers in advance:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
تمت ترجمة الإعلان تلقائياً، وقد تكون هنالك بعض الأخطاء في الترجمة.
مورد
ملاحظة: سجّل مجانًا أو سجّل الدخول، للاطلاع على جميع المعلومات.
مسجل منذ: 2012
تقديم الطلب
الهاتف & فاكس
+49 2861 ... إعلانات
قد تهمك أيضًا هذه الإعلانات.
إعلان صغير
Tata
٢٬٥٦١ km
جهاز قياس الإحداثيات بدون كمبيوتر
Mitutoyo EURO M547
Mitutoyo EURO M547
إعلان صغير
Brno-město
٢٬٧٧٦ km
تنسيق آلة قياس
MitutoyoCrysta Plus M544
MitutoyoCrysta Plus M544
إعلان صغير
Borken
٣٬٤٣٢ km
غرفة اختبار المناخ 335 لتر مع الرطوبة
VötschVCS 7034-5 -70°C bis +180°C
VötschVCS 7034-5 -70°C bis +180°C
إعلان صغير
Borken
٣٬٤٣٢ km
غرفة الاختبار المناخية
VötschVCS 7033
VötschVCS 7033
إعلان صغير
Borken
٣٬٤٣٢ km
غرفة الاختبار البيئي -70 درجة مئوية - + 180 درجة رطوبة
ThermotronSM-8-8200
ThermotronSM-8-8200
إعلان صغير
Wymysłów
٢٬٩٩٩ km
نظام القياس
Mitutoyo200-300mm
Mitutoyo200-300mm
إعلان صغير
Borken
٣٬٤٣٢ km
غرفة اختبار المناخ مع الرطوبة
Weiss -72°C bis +180°CWK3-340/70
Weiss -72°C bis +180°CWK3-340/70
إعلان صغير
Wiefelstede
٣٬٤٨٨ km
ارتفاع الكسارة
Mitutoyo192-104 0,01 - 600 mm
Mitutoyo192-104 0,01 - 600 mm
إعلان صغير
Wymysłów
٢٬٩٩٩ km
نظام القياس
Mitutoyo0-300mm
Mitutoyo0-300mm
إعلان صغير
Borken
٣٬٤٣٢ km
خزانة اختبار درجة الحرارة
VötschVTS 7034-5
VötschVTS 7034-5
تم حذف إعلانك بنجاح
حدث خطأ