This listing is for a Pacific Scientific 3313LL Met One Particle Counter
The unit is in full working condition and is ready for immediate release.
Kdedpfx Adexv Ab Holew
Operational & Practical Notes / Behavior
The 3313LL counts particles by passing a laser (or light source) through the sampled air stream; when particles pass through the beam, they scatter light, which is detected by a photodetector.
By having multiple size channels, the instrument can bin the counts into different particle-size ranges (for example: 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm).
It likely offers programmable sampling intervals, hold times, alarm thresholds, etc. (common features in Met One/Met One‑type instruments).
Data export via serial is standard, allowing integration with control or data acquisition systems.
Because it’s a relatively high‑flow device (1 CFM), it can sample a substantial volume of air (improving statistical confidence in counts).
The stainless steel construction helps with durability, cleanliness, and possibly resistance to corrosion or harsh environments.
As a used / legacy device, calibration, maintenance, and replacement parts (filters, laser, pump, optics) may be important considerations.
The unit is in full working condition and is ready for immediate release.
Kdedpfx Adexv Ab Holew
Operational & Practical Notes / Behavior
The 3313LL counts particles by passing a laser (or light source) through the sampled air stream; when particles pass through the beam, they scatter light, which is detected by a photodetector.
By having multiple size channels, the instrument can bin the counts into different particle-size ranges (for example: 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm).
It likely offers programmable sampling intervals, hold times, alarm thresholds, etc. (common features in Met One/Met One‑type instruments).
Data export via serial is standard, allowing integration with control or data acquisition systems.
Because it’s a relatively high‑flow device (1 CFM), it can sample a substantial volume of air (improving statistical confidence in counts).
The stainless steel construction helps with durability, cleanliness, and possibly resistance to corrosion or harsh environments.
As a used / legacy device, calibration, maintenance, and replacement parts (filters, laser, pump, optics) may be important considerations.
مورد