محلل غاز Hitech Instruments GIR250
Hitech Instruments GIR250

الحالة
مستعمل
الموقع
Duxford المملكة المتحدة
محلل غاز Hitech Instruments GIR250 Hitech Instruments GIR250
محلل غاز Hitech Instruments GIR250 Hitech Instruments GIR250
محلل غاز Hitech Instruments GIR250 Hitech Instruments GIR250
محلل غاز Hitech Instruments GIR250 Hitech Instruments GIR250
محلل غاز Hitech Instruments GIR250 Hitech Instruments GIR250
محلل غاز Hitech Instruments GIR250 Hitech Instruments GIR250
more Images
Hitech Instruments GIR250
Hitech Instruments GIR250
Hitech Instruments GIR250
Hitech Instruments GIR250
Hitech Instruments GIR250
Hitech Instruments GIR250
عرض الصور
عرض الخريطة

بيانات عن الآلة

وصف الآلة:
محلل غاز Hitech Instruments GIR250
المصنّع:
Hitech Instruments
الموديل:
GIR250
الحالة:
مستعمل

السعر والموقع

الموقع:
Duxford, UK المملكة المتحدة
اتصل

تفاصيل العرض

معرّف القائمة:
A20123055
الرقم المرجعي:
240850/7B
التحديث الأخير:
في ٠٢.١٠.٢٠٢٥

الوصف

This listing is for the Hitech Instruments GIR250 Gas Analyser

The unit is in full working condition and is ready for immediate use

The GIR250 is a bench‑top / transportable analyser designed to measure oxygen (O₂) and carbon dioxide (CO₂) simultaneously in gas samples.

It is made by Hitech Instruments (now part of the MTL / Eaton group).

Its design emphasizes ease of use, reliability, and low maintenance cost.

Other supporting features:
Dwjdpfx Aoxhdqtsalec

The instrument can be programmed with pass/fail criteria for each gas (alarms).

It provides analog outputs, typically 4–20 mA, for external logging or control systems.

Calibration is designed to be simple (via the front panel keypad) to reduce training burden.

The O₂ galvanic cell is user-replaceable (i.e. maintenance can be performed in the field).

Mechanical, Electrical & Operational Details

The GIR250 is housed in a rugged, transportable case (lab-style) so it can be used as a benchtop or mobile analyser.

Sample inlet and outlet connections use 0.25″ (~6 mm) tubing.

The sample system should avoid condensation and contaminants; non‑condensing sample environment is required.

Operating ambient temperature: –5 to +40 °C (for non‑condensing conditions)

Power / interface: standard for bench‑top analysers (the catalogue doesn’t always detail it, but likely mains or DC supply, suitable for lab use)

Typical Applications & Suitability

Because it can measure both O₂ and CO₂ in a single unit, the GIR250 is used in applications such as:

Respiration / breathing gas analysis / Douglas bag analysis (i.e. in physiological or experimental gas mixture measurement)

Fermentation / bioprocess monitoring (where O₂ and CO₂ both matter)

Gas mixture / inertisation / process gas quality (checking gas purity, calibrating mixtures)

It is not primarily intended for measuring very low trace levels (ppm-level) of O₂ or CO₂ unless its ranges are suitably adapted or specified. The design is more for percent-range analysis

مورد

آخر تواجد: الأسبوع الماضي

مسجل منذ: 2019

٥٢٤ إعلانات عبر الإنترنت

اتصل

تقديم الطلب

أرضus 
ألمانيا
النمسا
سويسرا
الولايات المتحدة الأمريكية
المملكة المتحدة
فرنسا
بلجيكا
إسبانيا
المكسيك
إيطاليا
هولندا
بولندا
الاتحاد الروسي
بيلاروس (جمهورية بيلاروس)
أوكرانيا
إستونيا
تركيا
نيوزيلندا
أيرلندا
جمهورية التشيك
الدانمارك
فنلندا
السويد
النرويج
لوكسمبورغ
اليونان
ليتوانيا
لاتفيا
آيسلندا
البرتغال
البرازيل
فنزويلا
الأرجنتين
المجر
سلوفاكيا
رومانيا
مولدوفا
سلوفينيا
صربيا
الجبل الأسود
ألبانيا
كرواتيا
بلغاريا
مقدونيا الشمالية
البوسنة والهرسك
إسرائيل
مصر
المغرب
الهند
إندونيسيا
كوريا الجنوبية
اليابان
تايلاند
ماليزيا
فيتنام
China
تايوان
إيران
بنغلاديش
أفغانستان
ملاحظة: سيتم إرسال طلبك إلى جميع البائعين في فئة الماكينات. وبهذه الطريقة يمكنك الحصول على العديد من العروض.
تعذر إرسال الطلب. يرجى المحاولة مرة أخرى لاحقًا.

الهاتف & فاكس

+44 20 38... إعلانات