مضخة محقنة للتسريب الطبي Fresenius Vial Pilot A2 (Perfusor)Fresenius
Pilot A2
مضخة محقنة للتسريب الطبي Fresenius Vial Pilot A2 (Perfusor)
Fresenius
Pilot A2
في بي بالإضافة إلى ضريبة القيمة المضافة
٢٢٦ €
الحالة
مستعمل
الموقع
Borken 

السعر والموقع
في بي بالإضافة إلى ضريبة القيمة المضافة
٢٢٦ €
- الموقع:
- Borken, ألمانيا

اتصل
تفاصيل العرض
- معرّف الإعلان:
- A23232139
- رقم المرجع:
- 74858
- تحديث:
- آخر مرة في 28.10.2026
وصف
Fresenius Pilot A2 Syringe Pump
You are bidding on an original Fresenius Vial Pilot A2 syringe pump (often also referred to as a perfusor).
This is a proven, highly precise medical table and stand device for the continuous and precisely dosed administration of medications and infusion solutions.
In everyday medical practice, the device is used for the continuous, precisely controlled administration of highly potent medications, anesthetics, or infusion solutions via standard syringes.
The device features a clear operating panel, a digital display for rate indication, and automatic safety and alarm functions.
Pjdpfxj Af Uyno Am Sjrc
Thanks to the already mounted, robust original bracket on the back, the pump can be securely attached to infusion stands, intensive care beds, or standardized medical rails in no time.
Features:
- High flexibility: Automatic detection and compatibility with common 20 ml and 50 ml Luer-Lock syringes (presets for BD Plastipak, Braun Perfusor, and Monoject, among others, can be read directly on the housing).
- Clear operating panel: Wipe-resistant, hygienic foil keyboard with a clear digital LED display for exact rate indication.
- Comprehensive safety system: Visual and audible pre-alarms and main alarms in case of occlusion, incorrect syringe positioning, power failure, or low battery.
- Mobility: Integrated battery for bridging during patient transport or sudden power failure.
Technical data:
Manufacturer: Fresenius Vial SA (Vial Medical)
Model: Pilot A2
Device type: Infusion syringe pump (perfusor)
Syringe compatibility: Suitable for standardized 20 ml and 50 ml Luer-Lock syringes
Delivery rate adjustable: from 0.1 to 400 ml/h
Accuracy: ± 1 % (drive mechanism), ± 2 % (syringe)
Power supply: Mains operation: 230 V ~ 50/60 Hz
Battery operation: Integrated battery (for power failure/transport)
Power consumption: Max. 23 VA
Dimensions (H x W x D): Approx. 120 x 330 x 155 mm
Weight: Approx. 2.2 kg
Housing material: Robust, impact-resistant polycarbonate
Safety features: Audible and visual alarm systems (e.g., in case of occlusion/pressure, syringe positioning, power failure, or low battery)
Year of manufacture: 2012
"Everything from one source: We would be happy to offer you suitable bank financing for your project."
You can find more new and used items in our shop!
International shipping costs on request!
تمت ترجمة الإعلان تلقائيًا. قد تحدث أخطاء في الترجمة.
You are bidding on an original Fresenius Vial Pilot A2 syringe pump (often also referred to as a perfusor).
This is a proven, highly precise medical table and stand device for the continuous and precisely dosed administration of medications and infusion solutions.
In everyday medical practice, the device is used for the continuous, precisely controlled administration of highly potent medications, anesthetics, or infusion solutions via standard syringes.
The device features a clear operating panel, a digital display for rate indication, and automatic safety and alarm functions.
Pjdpfxj Af Uyno Am Sjrc
Thanks to the already mounted, robust original bracket on the back, the pump can be securely attached to infusion stands, intensive care beds, or standardized medical rails in no time.
Features:
- High flexibility: Automatic detection and compatibility with common 20 ml and 50 ml Luer-Lock syringes (presets for BD Plastipak, Braun Perfusor, and Monoject, among others, can be read directly on the housing).
- Clear operating panel: Wipe-resistant, hygienic foil keyboard with a clear digital LED display for exact rate indication.
- Comprehensive safety system: Visual and audible pre-alarms and main alarms in case of occlusion, incorrect syringe positioning, power failure, or low battery.
- Mobility: Integrated battery for bridging during patient transport or sudden power failure.
Technical data:
Manufacturer: Fresenius Vial SA (Vial Medical)
Model: Pilot A2
Device type: Infusion syringe pump (perfusor)
Syringe compatibility: Suitable for standardized 20 ml and 50 ml Luer-Lock syringes
Delivery rate adjustable: from 0.1 to 400 ml/h
Accuracy: ± 1 % (drive mechanism), ± 2 % (syringe)
Power supply: Mains operation: 230 V ~ 50/60 Hz
Battery operation: Integrated battery (for power failure/transport)
Power consumption: Max. 23 VA
Dimensions (H x W x D): Approx. 120 x 330 x 155 mm
Weight: Approx. 2.2 kg
Housing material: Robust, impact-resistant polycarbonate
Safety features: Audible and visual alarm systems (e.g., in case of occlusion/pressure, syringe positioning, power failure, or low battery)
Year of manufacture: 2012
"Everything from one source: We would be happy to offer you suitable bank financing for your project."
You can find more new and used items in our shop!
International shipping costs on request!
تمت ترجمة الإعلان تلقائيًا. قد تحدث أخطاء في الترجمة.
مورد
ملاحظة: سجّل مجانًا أو سجّل الدخول، للاطلاع على جميع المعلومات.
آخر تواجد: الأسبوع الماضي
مسجل منذ: 2008
٥٣٦ إعلانات عبر الإنترنت
إرسال طلب
هاتف & فاكس
+49 2862 ... إعلانات
قد تهمك أيضًا هذه الإعلانات.
ناجح
تم إرسال رسالتك.
إعلان صغير
Borken
٣٬٤٤٠ km
مضخة حقن وتسريب طبية Fresenius Vial Pilot A2 (Perfusor)
FreseniusPilot A2
FreseniusPilot A2
ناجح
تم إرسال رسالتك.
إعلان صغير
Borken
٣٬٤٤٠ km
مضخة محقنة طبية للتسريب Fresenius Vial Pilot A2 (بيرفوسور)، مستعملة
FreseniusPilot A2
FreseniusPilot A2
ناجح
تم إرسال رسالتك.
إعلان صغير
Borken
٣٬٤٤٠ km
مضخة حقن وتسريب طبيّة Fresenius Vial Pilot A2 (بيرفيوزر)
FreseniusPilot A2
FreseniusPilot A2
تم حذف إعلانك بنجاح
حدث خطأ