دافئ: +50 درجة مئوية / +200 درجة مئوية بارد: -80 درجة مئوية / +100 درجة مئويةCTS Temperaturschock-Prüfschrank
TSS-70/130 130 Liter
دافئ: +50 درجة مئوية / +200 درجة مئوية بارد: -80 درجة مئوية / +100 درجة مئوية
CTS Temperaturschock-Prüfschrank
TSS-70/130 130 Liter
الحالة
مستعمل
الموقع
Borken 

عرض الصور
عرض الخريطة
بيانات عن الآلة
السعر والموقع
- الموقع:
- Einsteinstraße 8a, 46325 Borken, Deutschland

اتصل
تفاصيل العرض
- معرّف الإعلان:
- A21799043
- رقم المرجع:
- 25162
- تحديث:
- آخر مرة في ٢٧.٠٤.٢٠٢٦
وصف
CTS
Type: TSS-70/130
Water-cooled chiller unit
For sale is a high-quality thermal shock test chamber manufactured by CTS (Clima Temperatur Systeme), model TSS-70/130.
This device is designed for thermal shock testing and is commonly used in industry, research, and quality assurance.
Application fields:
- Material testing
- Aging tests
- Electronics and component testing
- Thermal shock and temperature cycling tests
Technical specifications:
Type: TSS-70/130
Test volume: 130 liters
Temperature range:
- Hot chamber: +50°C to +200°C
- Cold chamber: -80°C to +100°C
Heating rate: approx. 6 K/min from room temperature to +180°C
Cooling rate: approx. 4 K/min from room temperature to -60°C
Temperature deviation:
±1 K over time
±2 K spatially
Temperature change rate:
Max. 100 K/min on average for shock test cycles (without radiant heat)
Transfer rate:
≤ 15 min in the range -65°C to +200°C with 10 kg ICs
Transfer time:
< 10 seconds
Electrical data:
Connection: 400 V, 3/N, 50 Hz
Nominal power: approx. 16.7 kW
Nominal current: approx. 26.8 A
Site-side fuse: 32 A slow-blow
Connection: Cekon 32
Cooling system:
Nwedpfey Hkfdox Aghsf
Refrigerant: R404A / R23
Water-cooled, low noise, fully hermetic
Features and equipment:
- CTS control panel
- Microprocessor-controlled regulation and monitoring system
- Program operation (up to 100 test programs)
- Digital setpoint/actual value display
- RS232 interface
- 2 free switching channels for controlling test objects on-site
- Fault alarm with floating contact (rated for up to 30 V-DC, 2 A)
- EMC tested
Technical design:
- Hot and cold chambers
- Transport basket with spindle drive
- Test chamber / basket made of stainless steel, Material no. 1.4301
- Insert basket made of stainless steel wire
- Pipe duct NW 50 with closing plug
- Compressed air connection 1/4" male
- Pressureless condensate drain R 1/2" internal thread
- Safety door lock
- Lockable door with window
Dimensions as per installation drawing:
External dimensions approx.: 2335 x 940 x 1820 mm
Entry dimensions approx.: 1990 x 940 x 1652 mm
Test chamber dimensions: Height approx. 410 mm, Width approx. 480 mm, Depth approx. 660 mm
Window: 300 x 300 mm
Further data:
Degree of protection: IP 22
Sound pressure level: < 60 dB(A)
Weight: approx. 950 kg
Average power consumption per test cycle: approx. 8 kWh
For your assurance as a buyer, the following procedures are performed on all offered chambers beforehand:
1. Function check and replacement of necessary components
2. If required, recharge with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, chambers undergo a documented trial run
Condition: used
Scope of delivery: see pictures
(Specifications subject to change and errors excepted!)
If you have further questions, we are happy to assist you by phone.
تمت ترجمة الإعلان تلقائيًا. قد تحدث أخطاء في الترجمة.
Type: TSS-70/130
Water-cooled chiller unit
For sale is a high-quality thermal shock test chamber manufactured by CTS (Clima Temperatur Systeme), model TSS-70/130.
This device is designed for thermal shock testing and is commonly used in industry, research, and quality assurance.
Application fields:
- Material testing
- Aging tests
- Electronics and component testing
- Thermal shock and temperature cycling tests
Technical specifications:
Type: TSS-70/130
Test volume: 130 liters
Temperature range:
- Hot chamber: +50°C to +200°C
- Cold chamber: -80°C to +100°C
Heating rate: approx. 6 K/min from room temperature to +180°C
Cooling rate: approx. 4 K/min from room temperature to -60°C
Temperature deviation:
±1 K over time
±2 K spatially
Temperature change rate:
Max. 100 K/min on average for shock test cycles (without radiant heat)
Transfer rate:
≤ 15 min in the range -65°C to +200°C with 10 kg ICs
Transfer time:
< 10 seconds
Electrical data:
Connection: 400 V, 3/N, 50 Hz
Nominal power: approx. 16.7 kW
Nominal current: approx. 26.8 A
Site-side fuse: 32 A slow-blow
Connection: Cekon 32
Cooling system:
Nwedpfey Hkfdox Aghsf
Refrigerant: R404A / R23
Water-cooled, low noise, fully hermetic
Features and equipment:
- CTS control panel
- Microprocessor-controlled regulation and monitoring system
- Program operation (up to 100 test programs)
- Digital setpoint/actual value display
- RS232 interface
- 2 free switching channels for controlling test objects on-site
- Fault alarm with floating contact (rated for up to 30 V-DC, 2 A)
- EMC tested
Technical design:
- Hot and cold chambers
- Transport basket with spindle drive
- Test chamber / basket made of stainless steel, Material no. 1.4301
- Insert basket made of stainless steel wire
- Pipe duct NW 50 with closing plug
- Compressed air connection 1/4" male
- Pressureless condensate drain R 1/2" internal thread
- Safety door lock
- Lockable door with window
Dimensions as per installation drawing:
External dimensions approx.: 2335 x 940 x 1820 mm
Entry dimensions approx.: 1990 x 940 x 1652 mm
Test chamber dimensions: Height approx. 410 mm, Width approx. 480 mm, Depth approx. 660 mm
Window: 300 x 300 mm
Further data:
Degree of protection: IP 22
Sound pressure level: < 60 dB(A)
Weight: approx. 950 kg
Average power consumption per test cycle: approx. 8 kWh
For your assurance as a buyer, the following procedures are performed on all offered chambers beforehand:
1. Function check and replacement of necessary components
2. If required, recharge with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, chambers undergo a documented trial run
Condition: used
Scope of delivery: see pictures
(Specifications subject to change and errors excepted!)
If you have further questions, we are happy to assist you by phone.
تمت ترجمة الإعلان تلقائيًا. قد تحدث أخطاء في الترجمة.
إرسال طلب