نظام الكشف الكمي الفلوري Bioer Quant Gene 9600Bioer Quant Gene 9600
Gene 9600
نظام الكشف الكمي الفلوري Bioer Quant Gene 9600
Bioer Quant Gene 9600
Gene 9600
الحالة
مستعمل
الموقع
Duxford 

بيانات عن الآلة
- اسم الماكينة:
- نظام الكشف الكمي الفلوري Bioer Quant Gene 9600
- الشركة المصنعة:
- Bioer Quant Gene 9600
- طراز:
- Gene 9600
- الحالة:
- مستعمل
السعر والموقع
- الموقع:
- Duxford, UK

اتصل
تفاصيل العرض
- معرّف الإعلان:
- A20124805
- رقم المرجع:
- PR-001.SR4C
- تحديث:
- آخر مرة في 30.03.2026
وصف
This listing is for the Bioer Quant Gene 9600 Fluorescent Quantitative Detection System
The unit is in full working condition and is ready for immediate use
Bioer LineGene Plus 9600 FQD-96A – Fluorescent Quantitative Detection System
Key Specifications
Sample Capacity: 96-well 0.2 mL PCR plates, 12 × 8-strip tubes, or 96 × 0.2 mL single tubes (transparent bottom)
Reaction Volume: 5–100 µL
Dynamic Range: 1–10¹⁰ copies/µL
Detection Channels: 5 or 6 channels (F1–F6)
Excitation Wavelength: 300–800 nm
Emission Wavelength: 500–800 nm
Temperature Range: 4–105°C (0.1°C increments)
Lajdjxhgfgjpfx Ad Nod
Temperature Control Accuracy: ±0.1°C
Temperature Uniformity: ≤ ±0.3°C
Heating Rate: Up to 4.0°C/s
Cooling Rate: Up to 4.0°C/s
Hot Lid Temperature Range: 30–110°C (adjustable, default 105°C)
Gradient Temperature Range: 1–36°C
Scanning Mode: Full-plate scanning and designated line scanning (5.5 seconds per scan)
Programming: Up to 20 segments per program, up to 99 cycles
Operating System Compatibility: Windows 7/8/10
Software Requirements: Microsoft Excel 2000/2002/2003/2007/2012
Minimum Computer Configuration: RAM: 512 MB; Hard Disk: 10 GB; CPU: Pentium 4; Virtual Memory: ≥1000 MB
Power Supply: 100–240V, 50/60Hz, 600W
Dimensions: 410 mm (W) × 386 mm (D) × 352 mm (H)
Weight: Approximately 20 kg
Certifications: CE, EMC, RoHS2.0, MET
.
The unit is in full working condition and is ready for immediate use
Bioer LineGene Plus 9600 FQD-96A – Fluorescent Quantitative Detection System
Key Specifications
Sample Capacity: 96-well 0.2 mL PCR plates, 12 × 8-strip tubes, or 96 × 0.2 mL single tubes (transparent bottom)
Reaction Volume: 5–100 µL
Dynamic Range: 1–10¹⁰ copies/µL
Detection Channels: 5 or 6 channels (F1–F6)
Excitation Wavelength: 300–800 nm
Emission Wavelength: 500–800 nm
Temperature Range: 4–105°C (0.1°C increments)
Lajdjxhgfgjpfx Ad Nod
Temperature Control Accuracy: ±0.1°C
Temperature Uniformity: ≤ ±0.3°C
Heating Rate: Up to 4.0°C/s
Cooling Rate: Up to 4.0°C/s
Hot Lid Temperature Range: 30–110°C (adjustable, default 105°C)
Gradient Temperature Range: 1–36°C
Scanning Mode: Full-plate scanning and designated line scanning (5.5 seconds per scan)
Programming: Up to 20 segments per program, up to 99 cycles
Operating System Compatibility: Windows 7/8/10
Software Requirements: Microsoft Excel 2000/2002/2003/2007/2012
Minimum Computer Configuration: RAM: 512 MB; Hard Disk: 10 GB; CPU: Pentium 4; Virtual Memory: ≥1000 MB
Power Supply: 100–240V, 50/60Hz, 600W
Dimensions: 410 mm (W) × 386 mm (D) × 352 mm (H)
Weight: Approximately 20 kg
Certifications: CE, EMC, RoHS2.0, MET
.
مورد
ملاحظة: سجّل مجانًا أو سجّل الدخول، للاطلاع على جميع المعلومات.
مسجل منذ: 2019
٧٩١ إعلانات عبر الإنترنت
إرسال طلب
هاتف & فاكس
+44 20 38... إعلانات
قد تهمك أيضًا هذه الإعلانات.
إعلان صغير
Świdno
٢٬٨٣١ km
شاحنة صغيرة بيك أب
Mercedes-Benzsprinter 318
Mercedes-Benzsprinter 318
إعلان صغير
Győr
٢٬٥٩٠ km
جهاز تحليل غازات الدم
Instrumentation LaboratoryGEM Premier 4000
Instrumentation LaboratoryGEM Premier 4000
إعلان صغير
Piskorzów
٢٬٩٢٢ km
أوتوكلاف مختبر
SystecDE - 150
SystecDE - 150
تم حذف إعلانك بنجاح
حدث خطأ