جهاز التعقيم الدوار BARRIQUAND STERIFLOW 5BARRIQUAND STERIFLOW
STERIFLOW 5 J
جهاز التعقيم الدوار BARRIQUAND STERIFLOW 5
BARRIQUAND STERIFLOW
STERIFLOW 5 J
الحالة
مستعمل
الموقع
Lorquí 

عرض الصور
عرض الخريطة
بيانات عن الآلة
السعر والموقع
- الموقع:
- Polígono Industrial de Lorquí Parcela 129, 30564 Lorquí, ES
اتصل
تفاصيل العرض
- معرّف القائمة:
- A19237966
- الرقم المرجعي:
- 0000000196224
- التحديث الأخير:
- في ٢٧.٠٥.٢٠٢٥
الوصف
Autoclaves are used for the sterilization of packaged products that need to reach high temperatures (+100ºC) for the elimination or inactivation of pathogenic microorganisms.
Rotary autoclaves: they are used to sterilize products that present greater difficulties in heat transmission. Examples are vegetables in grains, grated or diced, and beverages such as milkshakes, teas, coffees or evaporated milk. In this type, the basket rotates on itself inside the autoclave, stirring the contents and preventing the pieces closest to the sides of the pot from roasting.
Steam consumption:
- Steam consumption: 350 kg.
- Required flow rate: 2400 kg/h
Guodpjwndcrsfx Abxeh
Cold water consumption:
- Cold water consumption: 8 m³.
- Required flow rate: 36 m³/h.
Compressed air consumption:
- Consumption per cycle: 11 Nm³
- Required flow rate: 110 Nm³/h
* Consumption may vary according to the cycle and temperature before and after sterilization.
Fluid pressures:
- Compressed air pressure 6 bar
- Steam pressure 4/5 bar
- Water pressure 3/5 bar
تمت ترجمة الإعلان تلقائياً، وقد تكون هنالك بعض الأخطاء في الترجمة.
Rotary autoclaves: they are used to sterilize products that present greater difficulties in heat transmission. Examples are vegetables in grains, grated or diced, and beverages such as milkshakes, teas, coffees or evaporated milk. In this type, the basket rotates on itself inside the autoclave, stirring the contents and preventing the pieces closest to the sides of the pot from roasting.
Steam consumption:
- Steam consumption: 350 kg.
- Required flow rate: 2400 kg/h
Guodpjwndcrsfx Abxeh
Cold water consumption:
- Cold water consumption: 8 m³.
- Required flow rate: 36 m³/h.
Compressed air consumption:
- Consumption per cycle: 11 Nm³
- Required flow rate: 110 Nm³/h
* Consumption may vary according to the cycle and temperature before and after sterilization.
Fluid pressures:
- Compressed air pressure 6 bar
- Steam pressure 4/5 bar
- Water pressure 3/5 bar
تمت ترجمة الإعلان تلقائياً، وقد تكون هنالك بعض الأخطاء في الترجمة.
مستندات
مورد
ملاحظة: سجّل مجانًا أو سجّل الدخول، للاطلاع على جميع المعلومات.
مسجل منذ: 2024
تقديم الطلب
الهاتف & فاكس
+34 968 6... إعلانات
تم حذف إعلانك بنجاح
حدث خطأ