مطياف الفلورسنتAgilent
Eclipse
مطياف الفلورسنت
Agilent
Eclipse
سنة الصنع
٢٠١٧
الحالة
مستعمل
الموقع
المملكة المتحدة 

عرض الصور
عرض الخريطة
بيانات عن الآلة
- وصف الآلة:
- مطياف الفلورسنت
- المصنّع:
- Agilent
- الموديل:
- Eclipse
- سنة الصنع:
- ٢٠١٧
- الحالة:
- جاهز للاستخدام (مستعمل)
السعر والموقع
- الموقع:
- Location:Duxford, United Kingdom
اتصل
تفاصيل العرض
- معرّف القائمة:
- A18143956
- الرقم المرجعي:
- 412977
- التحديث الأخير:
- في ٢٥.٠٢.٢٠٢٥
الوصف
Condition Used
Stock Number 412977
This listing is for a Agilent Eclipse Fluorescence Spectrometer.
The unit is in full working condition and is ready for immediate release.
Supplied with cables, software disk, License key,spare diffuser and Neutral density attenuator.
The Agilent Cary Eclipse fluorescence spectrometer is sensitive, accurate, and flexible. Ideal for use as a routine fluorometer, the Cary Eclipse can easily be switched between fluorescence, phosphorescence, chemiluminescence, and bioluminescence measurements. Additional flexibility can be achieved through various accessories, including temperature control and solid sample handling, automatic polarizers, and a microplate reader for high sample throughput.
Type:Benchtop fluorescence spectrometer
Control Software :Cary WinFLR
Kdjdpfxsvl A Aye Abxou
Light Source:Xenon flash lamp (80 Hz) with 10-year warranty on new instruments
Maximum Scanning Speed :24,000 nm/min
Modes of Operation:Fluorescence,Phosphorescence,Chemiluminescence,Biolumi nescence,Time resolved phosphorescence.
Power Requirements:100-240 VAC, 50/60 Hz
Spectral Bandwidth Emission: 1.5 nm, 2.5 nm, 5 nm, 10 nm, 20 nm 10 nm round nm
Excitation: 1.5 nm, 2.5 nm, 5 nm, 10 nm, 20 nm 10 nm round nm
Wavelength Accuracy:± 1.5 nm
Wavelength Range:Operational emission: 200 - 900 nm
Operational excitation: 200 - 900 nm
Depth:644 mm
Height:271 mm
Weight:30 kg
Width:608 mm
Stock Number 412977
This listing is for a Agilent Eclipse Fluorescence Spectrometer.
The unit is in full working condition and is ready for immediate release.
Supplied with cables, software disk, License key,spare diffuser and Neutral density attenuator.
The Agilent Cary Eclipse fluorescence spectrometer is sensitive, accurate, and flexible. Ideal for use as a routine fluorometer, the Cary Eclipse can easily be switched between fluorescence, phosphorescence, chemiluminescence, and bioluminescence measurements. Additional flexibility can be achieved through various accessories, including temperature control and solid sample handling, automatic polarizers, and a microplate reader for high sample throughput.
Type:Benchtop fluorescence spectrometer
Control Software :Cary WinFLR
Kdjdpfxsvl A Aye Abxou
Light Source:Xenon flash lamp (80 Hz) with 10-year warranty on new instruments
Maximum Scanning Speed :24,000 nm/min
Modes of Operation:Fluorescence,Phosphorescence,Chemiluminescence,Biolumi nescence,Time resolved phosphorescence.
Power Requirements:100-240 VAC, 50/60 Hz
Spectral Bandwidth Emission: 1.5 nm, 2.5 nm, 5 nm, 10 nm, 20 nm 10 nm round nm
Excitation: 1.5 nm, 2.5 nm, 5 nm, 10 nm, 20 nm 10 nm round nm
Wavelength Accuracy:± 1.5 nm
Wavelength Range:Operational emission: 200 - 900 nm
Operational excitation: 200 - 900 nm
Depth:644 mm
Height:271 mm
Weight:30 kg
Width:608 mm
مورد
ملاحظة: سجّل مجانًا أو سجّل الدخول، للاطلاع على جميع المعلومات.
مسجل منذ: 2019
تقديم الطلب
الهاتف & فاكس
+44 20 38... إعلانات
قد تهمك أيضًا هذه الإعلانات.
تم حذف إعلانك بنجاح